Loading the tool.
The figures appear here once the calculator has loaded. If nothing appears, reload the page or read the guide for a worked example.
The tool could not load its price data.
Nothing has been calculated, so no figures are shown. Please try again later.
Set a household heating budget, the home and its heating system to see the indoor temperature that budget reaches, what it costs to hold a safe temperature, and how fabric, heating system and tariff change both.
Result
°C
-
a week
- Weeks over budget
-
Indicative only. This is a steady-state model of one home, not a SAP, PHPP or HHSRS assessment. How this is calculated.
Health and compliance.
Tenant Power
Budget and temperature.
The indoor temperature this home reaches at each weekly heating budget, when it is outdoors.
- Safe, 18°C and above
- Marginal, 16°C to 18°C
- High risk, 12°C to 16°C
- Serious risk, below 12°C
View the chart as a table
| Weekly budget | Temperature reached | Band |
|---|---|---|
Heating systems compared.
The weekly cost of holding in this home () with each heating system and tariff, cheapest first. of fit within the budget.
Fabric and heating system.
The weekly cost of holding in a home, for each level of fabric and each heating system and tariff.
| Heating system and tariff | |
|---|---|
| This system |
Scroll sideways to see every level of fabric.
- Up to £15
- £15 to £25
- £25 to £40
- £40 to £60
- Over £60
- This home
This table compares the five standard levels of fabric, so it does not use the measured heat loss entered for this home.
The model treats Zero Bills as unavailable for solid wall and pre-1990 fabric.
Across the heating season.
The fuel needed to hold through the 30-week heating season, October to April, in typical weather for .
- Season fuel cost
- Average week
- Coldest week
Over the season the heating delivers kWh of heat. The season has degree-hours below a base temperature of , a measure of how much cold the heating has to make up.
View the 30 weeks as a table
| Week | Outdoor average | Fuel cost | Against budget |
|---|---|---|---|
Minimum Heat Guarantee.
The heating fuel cost of holding 16°C or 18°C through the 30-week heating season, for the region, home, heating system and tariff selected. Standing charges are not included, and these figures do not change with the target temperature.
How this is calculated.
The model treats the home as holding one steady temperature, where the heat going in equals the heat being lost. The steps below use the inputs you have chosen.
Show the worked example
Show the assumptions and price data
Assumptions
- Steady state: one continuous average heat input, with no thermal mass, setback or heat-up time.
- Heat loss is floor area multiplied by a heat loss figure for the fabric. That figure combines fabric and ventilation losses, so the ventilation rate is part of the fabric chosen.
- Internal gains are a flat 250 W from occupants, appliances and cooking.
- Solar gains are an illustrative 1.5 W per m² of floor area in mid-winter. The heating-season figures scale this by month, from 1.2 W in December to 5.5 W in April. Real values depend on glazing area, orientation and shading.
- Gas and oil boilers run at 78% efficiency at a high flow temperature, or 88% to 90% when condensing. A legacy heat pump has a seasonal performance factor (SPF) of 2.8. The Octopus Cosy heat pump uses its fleet average SPF of 3.91. All are fixed seasonal averages.
- In gas homes the weekly gas standing charge can be taken out of the budget before any energy is bought. Electricity standing charges are not counted, because every home has an electricity connection for its appliances whatever its heating. Oil has no standing charge.
- The indoor temperature is capped at 21°C, so the model never shows heating beyond full comfort.
- The heating season is 30 weeks, October to April, using typical weekly outdoor temperatures for each region.
- A Zero Bills home is assumed to hold the target temperature with no energy bill.
Energy prices
Tenant Power is priced at 30% below the standard electricity unit rate.
Temperature thresholds
- 18°C is the minimum indoor temperature the World Health Organization recommends for the general population, with around 21°C recommended for older people, children and people with long-term conditions.
- Below 16°C the Marmot Review (2011) links cold homes to thicker blood and a higher risk of heart attack and stroke.
- Temperatures below 12°C are associated with a risk of hypothermia.
- The Housing Health and Safety Rating System treats excess cold as a Category 1 hazard below 18°C in living areas.
- Awaab's Law requires landlords to investigate and act on damp and mould hazards. Cold homes carry a higher risk of both, especially where ventilation is poor.